Maintenance after daily use of fully automatic glassware washing machine
1. Clean the filter in the discharge box and install it after cleaning.
2. Open the quick drain valve to drain water, and clean the filter screen after draining.
3. Open the butterfly valve to discharge the pre-soaking liquid, open the cleaning hole cover of the pre-soaking tank, and flush the glass fragment channel with high-pressure water.
4. Open the stop valve, rinse the warm water tank and hot water tank respectively with clean water, and then close the stop valve and the main clean water valve after rinsing.
5. Clean up the debris, dirt, glass fragments, etc. around the instrument. 6. Clean the bottle discharge area, close the quick drain valve, and refill the instrument with oil.
STIER (Guangzhou) Instrument Co., Ltd.
Address: 207, Building 4, Qixi Creative Industrial Park, No. 24 Xinyi Road, Liwan District, Guangzhou, China
Telephone: +86-20-81579281
E-mail:info@stier-instrument.com
Website: www.stier-instrument.com
L100 Lower Basket
• For holding up to 2 injector modules or inserts
• H 152, W 530, D 553mm
A306D 3×6 Module(150 mm)
• Suitable for laboratory glassware such as Erlenmeyer flasks, round bottom flasks, Eggplant shaped bottle, Schott flask, beaker, etc.
• 18 × S601508D injector nozzles(H 150 mm)
• H 183, W 184, D 472 mm
3L9 3×3 Module
• Suitable for laboratory glassware such as Schott flask,
Erlenmeyer flasks, separatory funnel ,volumetric flasks, etc.
• H 282, W 530, D 551 mm
Maintenance after daily use of fully automatic glassware washing machine
1. Clean the filter in the discharge box and install it after cleaning.
2. Open the quick drain valve to drain water, and clean the filter screen after draining.
3. Open the butterfly valve to discharge the pre-soaking liquid, open the cleaning hole cover of the pre-soaking tank, and flush the glass fragment channel with high-pressure water.
4. Open the stop valve, rinse the warm water tank and hot water tank respectively with clean water, and then close the stop valve and the main clean water valve after rinsing.
5. Clean up the debris, dirt, glass fragments, etc. around the instrument. 6. Clean the bottle discharge area, close the quick drain valve, and refill the instrument with oil.
STIER (Guangzhou) Instrument Co., Ltd.
Address: 207, Building 4, Qixi Creative Industrial Park, No. 24 Xinyi Road, Liwan District, Guangzhou, China
Telephone: +86-20-81579281
E-mail:info@stier-instrument.com
Website: www.stier-instrument.com