B021
STIER
A306B 3×6 Module(210 mm)
• Suitable for laboratory glassware such as volumetric flasks,
Erlenmeyer flasks, round bottom flasks, Schott flask, measuring cylinder, etc.
• 18 × S602106A injector nozzles(H 210 mm)
• H 243, W 184, D 472 mm
A306E 3×6 Module(150 mm)
• Suitable for laboratory glassware such as Sampling bottle,
Erlenmeyer flasks, round bottom flasks, Eggplant shaped bottle, Schott flask, beaker, etc.
• 18 × S601508E injector nozzles(H 150 mm)
• H 183, W 184, D 472 mm
Cleaning of new glassware with a laboratory glassware cleaning machine: Free alkaline substances are often attached to the surface of new glassware, which need to be neutralized and removed with acid. The original hand washing method is: scrub with synthetic detergent or soapy water, rinse, then soak in dilute hydrochloric acid for more than 4 hours, and then inject concentrated hydrochloric acid to cover the entire inner wall of the vessel for a few minutes until it is rinsed clean. For machine washing, you can first rinse with room temperature water, and then use our glassware cleaning program.
STIER (Guangzhou) Instrument Co., Ltd.
Address: 207, Building 4, Qixi Creative Industrial Park, No. 24 Xinyi Road, Liwan District, Guangzhou, China
Telephone: +86-20-81579281
E-mail:info@stier-instrument.com
Website: www.stier-instrument.com
A306B 3×6 Module(210 mm)
• Suitable for laboratory glassware such as volumetric flasks,
Erlenmeyer flasks, round bottom flasks, Schott flask, measuring cylinder, etc.
• 18 × S602106A injector nozzles(H 210 mm)
• H 243, W 184, D 472 mm
A306E 3×6 Module(150 mm)
• Suitable for laboratory glassware such as Sampling bottle,
Erlenmeyer flasks, round bottom flasks, Eggplant shaped bottle, Schott flask, beaker, etc.
• 18 × S601508E injector nozzles(H 150 mm)
• H 183, W 184, D 472 mm
Cleaning of new glassware with a laboratory glassware cleaning machine: Free alkaline substances are often attached to the surface of new glassware, which need to be neutralized and removed with acid. The original hand washing method is: scrub with synthetic detergent or soapy water, rinse, then soak in dilute hydrochloric acid for more than 4 hours, and then inject concentrated hydrochloric acid to cover the entire inner wall of the vessel for a few minutes until it is rinsed clean. For machine washing, you can first rinse with room temperature water, and then use our glassware cleaning program.
STIER (Guangzhou) Instrument Co., Ltd.
Address: 207, Building 4, Qixi Creative Industrial Park, No. 24 Xinyi Road, Liwan District, Guangzhou, China
Telephone: +86-20-81579281
E-mail:info@stier-instrument.com
Website: www.stier-instrument.com