Availability: | |
---|---|
Quantity: | |
4L16
STIER
U100 Upper Basket
• For holding up to 2 injector modules or inserts
• H 157, W 530, D 553 mm
A306A 3×6 Module(210 mm)
• Suitable for laboratory glassware such as volumetric flasks,
Erlenmeyer flasks, round bottom flasks, Schott flask, measuring cylinder, etc.
• 18 × S602108C injector nozzles(H 210 mm)
• H 243, W 184, D 472 mm
A306B 3×6 Module(210 mm)
• Suitable for laboratory glassware such as volumetric flasks,
Erlenmeyer flasks, round bottom flasks, Schott flask, measuring cylinder, etc.
• 18 × S602106A injector nozzles(H 210 mm)
• H 243, W 184, D 472 mm
L100 Lower Basket
• For holding up to 2 injector modules or inserts
• H 152, W 530, D 553mm
C16 4×4 Module
• Suitable for laboratory glassware such as Schott flask,
Erlenmeyer flasks, separatory funnel ,volumetric flasks, etc.
• H 234, W 530, D 551 mm
Maintenance points
1. Do not open the door at will during the operation of the laboratory cleaning machine to avoid heat loss and affect the drying effect (hot steam may also cause injuries to experimenters). The STIER bottle washing machine is equipped with a high-efficiency steam condenser, which will not discharge steam into the room, reducing safety hazards.
2. Cut off the water source after each use and open the door slightly to avoid moisture and odor. Gently wipe the instrument with a soft cloth and let it dry completely.
3. The weather is cold and the inlet water temperature is low. You should pay attention to the following two points:
(1) If the water temperature is too low, the power consumption of the heating device will increase, so the equipment should be descaled.
(2) If the inlet water temperature is too low, spots or films may appear on the cleaned glassware. It is recommended to start the instrument and let it run for 18 to 22 minutes before entering the main washing stage.
STIER (Guangzhou) Instrument Co., Ltd.
Address: 207, Building 4, Qixi Creative Industrial Park, No. 24 Xinyi Road, Liwan District, Guangzhou, China
Telephone: +86-20-81579281
E-mail:info@stier-instrument.com
Website: www.stier-instrument.com
U100 Upper Basket
• For holding up to 2 injector modules or inserts
• H 157, W 530, D 553 mm
A306A 3×6 Module(210 mm)
• Suitable for laboratory glassware such as volumetric flasks,
Erlenmeyer flasks, round bottom flasks, Schott flask, measuring cylinder, etc.
• 18 × S602108C injector nozzles(H 210 mm)
• H 243, W 184, D 472 mm
A306B 3×6 Module(210 mm)
• Suitable for laboratory glassware such as volumetric flasks,
Erlenmeyer flasks, round bottom flasks, Schott flask, measuring cylinder, etc.
• 18 × S602106A injector nozzles(H 210 mm)
• H 243, W 184, D 472 mm
L100 Lower Basket
• For holding up to 2 injector modules or inserts
• H 152, W 530, D 553mm
C16 4×4 Module
• Suitable for laboratory glassware such as Schott flask,
Erlenmeyer flasks, separatory funnel ,volumetric flasks, etc.
• H 234, W 530, D 551 mm
Maintenance points
1. Do not open the door at will during the operation of the laboratory cleaning machine to avoid heat loss and affect the drying effect (hot steam may also cause injuries to experimenters). The STIER bottle washing machine is equipped with a high-efficiency steam condenser, which will not discharge steam into the room, reducing safety hazards.
2. Cut off the water source after each use and open the door slightly to avoid moisture and odor. Gently wipe the instrument with a soft cloth and let it dry completely.
3. The weather is cold and the inlet water temperature is low. You should pay attention to the following two points:
(1) If the water temperature is too low, the power consumption of the heating device will increase, so the equipment should be descaled.
(2) If the inlet water temperature is too low, spots or films may appear on the cleaned glassware. It is recommended to start the instrument and let it run for 18 to 22 minutes before entering the main washing stage.
STIER (Guangzhou) Instrument Co., Ltd.
Address: 207, Building 4, Qixi Creative Industrial Park, No. 24 Xinyi Road, Liwan District, Guangzhou, China
Telephone: +86-20-81579281
E-mail:info@stier-instrument.com
Website: www.stier-instrument.com